The TR & TRS Series / Class RK5 / Time Delay is part of the Mersen (formerly Ferraz Shawmut) general purpose fuses line, distributed by Gross Automation.

TR & TRS Series / Class RK5 / Time Delay

The industry's most popular fuse for motor circuit protection - Tri-Onic® SmartSpot® TR fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the TR current limiting time delay fuses are engineered for overcurrent protection of motors and transformers, service entrance equipment, feeder and branch circuits. Tri-onic's proven time delay characteristic safely handles harmless starting currents and inrush currents associated with today's motors and transformers.

Specifications

SpecificationValue
RatingsTR: AC - 1/10 to 600A, 250VAC, 200kA I.R.; TRS: AC - 1/10 to 600A, 600VAC, 200kA I.R.; TR: DC - 1/10 to 2-8/10A, 250VDC, 20kA I.R. 3 to 30A, 160VDC, 20kA I.R. 35 to 400A, 250VDC, 20kA I.R. 450 to 600A, 160VDC, 20kA I.R.; TRS: DC - 1/10 to 12A, 600VDC, 20kA I.R. 15 to 60A, 300VDC, 20kA I.R. 70 to 600A, 600VDC, 20kA I.R.; UL Listed to Standard 248-12; CSA Certified to Standard C22.2 No. 248.12; DC Tested to UL 198L limits (Ferraz Shawmut Certified); Some Ratings RoHS Compliant; Motor Circuits; Mains; Feeders; Branch Circuits; Transformers; Service Entrance Equipment; General-purpose Protection
FeaturesSolid-State SmartSpot Indicator; Time delay for motor start-ups and transformer inrush currents without nuisance opening; Current limiting for low peak let-thru current; Rejection-style design prevents replacement errors (when used with recommended fuse block); Time Delay; Current limiting; AC & DC Rated

Features

  • Solid-State SmartSpot Indicator
  • Time delay for motor start-ups and transformer inrush currents without nuisance opening
  • Current limiting for low peak let-thru current
  • Rejection-style design prevents replacement errors (when used with recommended fuse block)
  • Time Delay
  • Current limiting
  • AC & DC Rated

Ratings

  • TR: AC - 1/10 to 600A, 250VAC, 200kA I.R.
  • TRS: AC - 1/10 to 600A, 600VAC, 200kA I.R.
  • TR: DC - 1/10 to 2-8/10A, 250VDC, 20kA I.R. 3 to 30A, 160VDC, 20kA I.R. 35 to 400A, 250VDC, 20kA I.R. 450 to 600A, 160VDC, 20kA I.R.
  • TRS: DC - 1/10 to 12A, 600VDC, 20kA I.R. 15 to 60A, 300VDC, 20kA I.R. 70 to 600A, 600VDC, 20kA I.R.
  • UL Listed to Standard 248-12
  • CSA Certified to Standard C22.2 No. 248.12
  • DC Tested to UL 198L limits (Ferraz Shawmut Certified)
  • Some Ratings RoHS Compliant
  • Motor Circuits
  • Mains
  • Feeders
  • Branch Circuits
  • Transformers
  • Service Entrance Equipment
  • General-purpose Protection

Catalog Numbers

Catalog NumberColumn 2Column 3Column 4Column 5Column 6Column 7Column 8Column 9
1/10TR1/10RTRS1/10R3-1/2TR3-1/2RTRS3-1/2R50TR50RTRS50R
15/100TR15/100RTRS15/100R4TR4RTRS4R60TR60RTRS60R
2/10TR2/10RTRS2/10R4-1/2TR4-1/2RTRS4-1/2R70TR70RTRS70R
3/10TR3/10RTRS3/10R5TR5RTRS5R75TR75RTRS75R
4/10TR4/10RTRS4/10R5-6/10TR5-6/10RTRS5-6/10R80TR80RTRS80R
1/2TR1/2RTRS1/2R6TR6RTRS6R90TR90RTRS90R
6/10TR6/10RTRS6/10R6-1/4TR6-1/4RTRS6-1/4R100TR100RTRS100R
8/10TR8/10RTRS8/10R7TR7RTRS7R110TR110RTRS110R
1TR1RTRS1R8TR8RTRS8R125TR125RTRS125R
1-1/8TR1-1/8RTRS1-1/8R9TR9RTRS9R150TR150RTRS150R
1-1/4TR1-1/4RTRS1-1/4R10TR10RTRS10R175TR175RTRS175R
1-4/10TR1-4/10RTRS1-4/10R12TR12RTRS12R200TR200RTRS200R
1-6/10TR1-6/10RTRS1-6/10R15TR15RTRS15R225TR225RTRS225R
1-8/10TR1-8/10RTRS1-8/10R17-1/2TR17-1/2RTRS17-1/2R250TR250RTRS250R
2TR2RTRS2R20TR20RTRS20R300TR300RTRS300R
2-1/4TR2-1/4RTRS2-1/4R25TR25RTRS25R350TR350RTRS350R
2-1/2TR2-1/2RTRS2-1/2R30TR30RTRS30R400TR400RTRS400R
2-8/10TR2-8/10RTRS2-8/10R35TR35RTRS35R450TR450RTRS450R
3TR3RTRS3R40TR40RTRS40R500TR500RTRS500R
3-2/10TR3-2/10RTRS3-2/10R45TR45RTRS45R600TR600RTRS600R